Cold climate challenges addressed in new publication from ASHRAE


Buildings in arctic and subarctic climates face not only challenges related to cold but also remoteness, limited utilities, permafrost and extreme temperature shifts. Designers must meet these challenges while keeping occupants comfortable and minimizing impact on the environment.

The newly published “Cold-Climate Buildings Design Guide” from ASHRAE provides information on the issues commonly faced by designers in these climates. The idea for the guide came from a working session at the 7th International Cold-Climate Design Conference held in 2012 and co-sponsored by ASHRAE, SCANVAC and REHVA.

“Harmonizing human comfort with the climatic realities of these environments is a balancing act,” Erich Binder, who oversaw the writing of the guide, said. “Strategic design is key to building, commissioning and operating efficient and long-lasting cold-climate structures.”

A cold climate is defined by a combination of factors that create a unique set of building design challenges. These factors include temperature, frozen precipitation, wind, humidity, thermal comfort, thermal envelope/enclosure, maintainability, permafrost and frozen ground and remote building locations.

Following are tips from several committee members for designing, operating and maintaining buildings and systems in cold climates:

What happens when building air exfiltrates a building envelope in cold weather is similar to what happens in cooling coils in hot humid weather – understanding psychrometrics is essential to understanding building envelope performance in cold climates.

The colder the climate, the more important it is for critical equipment to be sheltered – you can’t expect service personnel to properly repair HVAC equipment in a winter blizzard. 

In extreme climates, windblown snow takes on a consistency similar to sand and requires special design techniques to keep it from getting into the HVAC intakes.

The manual also covers the design impacts from non-mechanical components of a facility such as the building envelope and roof construction. For instance, snow and ice sliding down of a metal roof can shear off mechanical roof penetrations as well as hoods on the exterior wall below.

A building envelope must address all modes of heat loss to be truly efficient; ignoring any mode of loss may lead to excessive thermal transfer.

Frost can be devastating for HVAC equipment, blocking intake hoods, filters, coils, etc.

Design out cold bridges in both building fabric and engineering penetrations.

Avoid or minimize any external service pipe runs.

Locate air inlets and exhausts in locations that avoid snow drift and blockage.

Ensure condensing pipes never freeze and block.

Provide safe access to roof mechanical plants in all weathers – frozen roof surfaces can be a hazard.

Frank Mills, who helped write the guide, noted that the book applies to all climates that have a heating season, not just the very cold ones.

“We do cover the extreme cold climates very well, but we also have very useful information for any buildings which have heating for part of the year,” he said. “This covers a lot of climate regions – including Europe where I am.”

In addition to cold-climate considerations in HVAC calculations and system design, this book’s chapters cover sustainability, controls, building design, and commissioning, all from this distinctive climatic perspective. The book also includes an appendix with seven case studies of buildings located in cold and extreme cold climates. These buildings are leaders in their field with regard to both efficiency and cold-climate design.

The cost of the “Cold-Climate Buildings Design Guide” is $90 ($77, ASHRAE members).

To order, visit www.ashrae.org/bookstore or contact ASHRAE Customer Contact Center at 1-800-527-4723 (United States and Canada) or 404-636-8400 (worldwide) or fax 678-539-2129.



October 19, 2015


Topic Area: Press Release


Recent Posts

Bugs Without Borders: The Coming HAI Crisis

A tsunami of pathogenic threats to healthcare facilities is not unthinkable. Simple cleaning might be a key defense.


Deadly Patient Assault Breaks Out at Fulton State Hospital

The suspect was charged with first degree murder and fourth degree assault in connection to the death of another patient after an alleged assault.


County of Santa Clara to Acquire Regional Medical Center from HCA Healthcare

The 258-bed hospital was purchased for $150 million.


Designing Senior Care Facilities with Veterans in Mind

Veterans have unique needs that go beyond the typical design for senior care facilities.


All Children's Specialty Physicians Outpatient Care Opens in Wesley Chapel Area

The center is a precursor to the construction of a new 56-bed Johns Hopkins All Children’s Hospital in Wesley Chapel.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.