Fresh-Aire UV Introduces Surface Disinfection UV Light System for Healthcare Facilities


Fresh-Aire UV®, Jupiter, Fla., a manufacturer of UV, gas phase carbon media air filtration and PCO air purification products, has introduced the Environmental Surface Disinfection System (ESDS), a stationary ceiling-mounted ultraviolet (UV) light system for irradiating potential Healthcare Associated Infections (HAI) pathogens on high-touch surfaces.  

The ESDS is a No-Touch-Disinfection (NTD), fully-customizable system designed for healthcare rooms and spaces requiring surface disinfection. The UV system complements conventional terminal cleaning practices used in disinfecting surgery suites, patient rooms and clean rooms in between occupied periods.

Versus mobile robotic UV methods, the stationary, fully-automatic hands-free disinfection solution has no moving parts, no maintenance needs other than quick and easy lamp replacement. The system is less susceptible to shadowing, requires no skilled technician or training and is considerably more cost-effective resulting in significant cost savings.

The product line consists of several sizes of dual or single power-coated white aluminum, commercial-grade fixture housings and lifetime warranty 120 or 230-volt power supplies. The fixtures range up to 60-inches-long and can be mounted in tandem for maximum disinfection dosage and coverage in any size room.  The fixture installs quickly to any ceiling material or height and requires the same skills as conventional light fixture installation.

ESDS lamps have an ozone-free, 254-nanometer UV spectrum, 12,000-hour lifecycle, and a shatter-proof Teflon® bulb coating encapsulation option. Besides surface disinfection, the system also disinfects airborne biological contaminants that pass through the UV field via air convection. Typical disinfection cycles are between 10 to 20 minutes. The ESDS is third-party laboratory tested as 99.9999-percent effective against disinfecting a cross-section of different microorganisms. 

Safety features include a programmable timer for activation only during unoccupied periods, an optional door-mounted interlock switch and infrared, motion and ultrasonic detectors that prevent accidental exposure. The ESDS can be combined with Fresh-Aire UV's Control Panel with a programmable logic controller (PLC) or it is  customizable for control and monitoring by building management systems (BMS).

Other ESDS features are:

·       Fresh-Aire UV's proprietary Blue-Calc Software can calculate and report "real-time" UV dosage and system placement for optimal performance.

·       wall-mounting capabilities for unique applications;

·       and a design that complements other good sanitation processes, such as manual disinfection methods by-hand;

Design assistance for engineers, contractors and maintenance staffs is available by the Fresh-Aire UV's engineering team for proper ESDS specifications, such as room orientation, layout, room equipment, placement, µW s/cm2rates, targeted pathogen deactivation, coverage distances and other parameters critical for maximum surface and airspace disinfection protection.

The ESDS is based on the 28 years of UV disinfection experience of Fresh-Aire UV, the leading North American manufacturer of UV manufacturing and innovation.

For more information on Fresh-Aire UV and its full line of commercial and residential UVC, APCO and other IAQ products, please visit www.freshaireuv.com

 



September 16, 2016


Topic Area: Press Release


Recent Posts

Healthcare Real Estate: Challenges and Industry Shifts for 2025

The hurdles include balancing expansion with financial constraints, the sustainability of office and retail conversions, and technological disruptions.


Geisinger to Build $32 Million Cancer Center in Pennsylvania

The two-story, 40,000-square-foot facility will be home to the cancer center with space for future growth of services.


Sunflower Medical Group Experiences Data Breach

To date, Sunflower has no evidence that personal information has been misused.


Strategies to Eradicate Biofilm Containing C. Auris

Understanding the speed and risks of contamination after room disinfection should inform managers’ environmental cleaning recommendations.


Man Attacks Nurses, Police Officer at Jefferson Hospital

The man allegedly attacked the staff members before being restrained and sedated.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.