ILAT from Inelta: Inductive Path Sensors in Miniature Format


The new Inelta ILAT Series Miniature LVDT Sensors provide precision measurements of position and path in the range of single-digit millimeters.  The sensors of this series are available in Models ILAT 2, ILAT4 and ILAT10 for the exact measurements of ±1 mm, ±2 mm or ±5 mm traveling distances. Owing to their tiny dimensions with a housing length of 79 mm and a diameter of only 8 mm at a weight of 30 g (including cable), the sensors will navigate even within very tight-fitting conditions.

Because of the inductive LVDT principle (Linear Variable Differential Transformer), in which a coil within the sensor with a primary winding and two secondary windings transforms the linear motions of the measuring sensor contact-free into a single electronic signal, the ILAT Sensors operate free from wear and provide a linearity tolerance of <0.25%. They are also available with an even smaller linearity tolerance of <0.1%.

Even with their tiny dimensions, the ILAT Sensors are distinguished by their robust design with a stainless-steel housing in protection class IP65 – optionally also in IP67.  Nominal temperature rating is 0° – 70°C.   The carefully designed linear guiding operates by virtue of a locking mechanism of the probe and can provide more than 10 million cycles.  These versatile sensors are suitable for many applications, including medical technology, engineering, agriculture and navigation up to testing facilities or manufacture of special purpose machinery. 

Fitting the ILAT Path Sensors are the Inelta external sensor amplifiers IMA2-LVDT, available for signals in the ranges of 0..5V, 0..10V, ±5V, ±10V, 0/4..20mA and ISM-LVDT for 0…10V- or 0..20mA signals.  Our print module IVM-LVDT with a readout of 0..10V signals, is also available, suitable for integration into your electronics. 

Additionally, Inelta can provide custom sensor designs with further optional features such as custom-made calibration, cable lengths and expanded temperature ranges. For more information, please visit http://www.hoffmann-krippner.com/sensors-displacement.html or call us at 770-487-1950.

 

 



June 26, 2017


Topic Area: Press Release


Recent Posts

Disinfectant Dispensers in Healthcare Facilities Often Fail to Deliver Safe Concentrations: Study

Study of 10 hospitals finds 90 percent have at least one dispenser delivering disinfectants at incorrect concentrations.


Duke University Health System Receives $50 Million for Proton Beam Therapy Center

The donation is the largest philanthropic gift received by Duke University Health System.


UT Southwestern Experiences Data Breach Through Calendar Tool

The incident occurred in October.


Protecting Patient Data: Strategies and Tactics

As cyber threats and breaches grow, healthcare organizations and facilities need a better approach to cybersecurity.


Duke Health to Acquire Lake Norman Regional Medical Center

The closing is projected for the first quarter of 2025.


 
 


FREE Newsletter Signup Form

News & Updates | Webcast Alerts
Building Technologies | & More!

 
 
 


All fields are required. This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
 
 

Healthcare Facilities Today membership includes free email newsletters from our facility-industry brands.

Facebook   Twitter   LinkedIn   Posts

Copyright © 2023 TradePress. All rights reserved.